LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

Printing note: Print the file using the function of the browser and select the settings "print background colors and images". Otherwise, the component-image does not show. You can also create PDF files the same way. For example, with the CutePDFTMWriter.

EGGER OSB 4 TOP

Lignum ID-№
OSB.006
Produktfamilie
Wood materials
Product group
Oriented strand board (OSB)
Material characteristics
Wood materials
Material type
Organically renewable
Statics HBT2
Functions
Humid environment
Areas of application
Covering / Structure / Bearing / Planking / Blanket / Humid environment
Construction product standard / ETA

QR

Further information

Search
HHG
VOC

Grafik

EGGER OSB 4 TOP

Hersteller

Egger EGGER OSB 4 TOP

Thickness [mm]

1 30 mm
2 40 mm

Details

ppm formaldehyde (EN 717-1) * No added formaldehyde
Adhesive, content [%] PMDI, 4-6%
Flammability group RF3
Klassifizierung D-s2,d0
Faserrichtung Lengthwise

Physical properties

Mittlere Rohdichte ρ 600 kg/m3
Heat conductivity λ 0.13 W/mK
Heat capacity 1700 J / kgK
Vapour barrier value (dry) 200
Vapour barrier value (damp) 200

Holzarten

Variante 1

ABAL Abies alba ( Silver fir; European silver fir )
PCAB Picea abies ( Norway Spruce )
PNSY Pinus sylvestris ( Scots Pine Redwood; Scots pine )

Variante 2

PCAB Picea abies ( Norway Spruce )
PONG Populus nigra ( Poplar; Black Poplar )
POXX Populus hybrid ( Poplar )

KBOB-Daten

Category Holz und Holzwerkstoffe
Designation building material OSB Platte, PF-gebunden, Feuchtbereich
UUID number BD66B05D-27E3-4ADF-85A2-E0ABBBA686A5
KBOB ID-№ Production 07.013
KBOB ID-№ Disposal 91.145
Designation Disposal Entsorgung, Spanplatte, 10% Bindemittel
mass per volume 605 kg/m3
Declared unit kg
Last Update 28.11.2024

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

Density (ρ) Thickness (d) Width (b) Länge [l] bSDD Properties
[kg/m3] [mm] [mm] [mm] Indicators Modules
Values / kg Values / dm3 Values / m2 Values / lm Values / Pc.
+
Environmental impact points (UBP)
1030
UBP'21/kg
618
UBP'21/dm3
Choose
UBP'21/m2
Choose
UBP'21/m'
Choose
UBP'21/pc.
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
922
UBP'21/kg
553
UBP'21/dm3
Choose
UBP'21/m2
Choose
UBP'21/m'
Choose
UBP'21/pc.
A1-A3
 
Environmental impact points from disposal (UBP_dis)
106
UBP'21/kg
64
UBP'21/dm3
Choose
UBP'21/m2
Choose
UBP'21/m'
Choose
UBP'21/pc.
C1-C4
+
Total primary energy (PE_T)
11.00
kWh oil-eq/kg
7
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
10.90
kWh oil-eq/kg
7
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
5.23
kWh oil-eq/kg
3
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
5.63
kWh oil-eq/kg
3
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy from disposal (PE_dis)
0.10
kWh oil-eq/kg
0
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
C1-C4
+
Renewable primary energy (PE_RT)
8.26
kWh oil-eq/kg
5
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
8.25
kWh oil-eq/kg
5
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
3.16
kWh oil-eq/kg
2
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
5.09
kWh oil-eq/kg
3
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
6.24
kWh oil-eq/kg
4
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
2.71
kWh oil-eq/kg
2
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
2.61
kWh oil-eq/kg
2
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
2.08
kWh oil-eq/kg
1
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0.54
kWh oil-eq/kg
0
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9.77
kWh oil-eq/kg
6
kWh oil-eq/dm3
Choose
kWh oil-eq/m2
Choose
kWh oil-eq/m'
Choose
kWh oil-eq/pc.
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0.56
kg CO2-eq/kg
0
kg CO2-eq/dm3
Choose
kg CO2/m2
Choose
kg CO2-eq/m'
Choose
kg CO2-eq/pc.
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0.48
kg CO2-eq/kg
0
kg CO2-eq/dm3
Choose
kg CO2/m2
Choose
kg CO2-eq/m'
Choose
kg CO2-eq/pc.
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.98
kg CO2-eq/kg
5
kg CO2-eq/dm3
Choose
kg CO2/m2
Choose
kg CO2-eq/m'
Choose
kg CO2-eq/pc.
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
1.63
kg CO2-eq/kg
1
kg CO2-eq/dm3
Choose
kg CO2/m2
Choose
kg CO2-eq/m'
Choose
kg CO2-eq/pc.
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0.44
kg C/kg
0
kg C/dm3
Choose
kg C/m2
Choose
kg C/m'
Choose
kg C/pc.
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)