Filter Catalog Floor assembly

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 2 of 27. There were 530 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

A0227

Ribs / joists 450 mm 66 dB 49 dB
On-lying material: Anhydrite
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 277 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.3 W/m2K -7 dB 5 dB
Detail IFC4 LOD300 XLSX

A0228

Ribs / joists 450 mm 64 dB 51 dB
On-lying material: Anhydrite
Additional insulation: Expanded polystyrene (EPS)
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 275 kg/m2 -3 dB 1 dB
Verified calculation ≈ 0.315 W/m2K -7 dB 4 dB
Detail IFC4 LOD300 XLSX

A0229

Ribs / joists 410 mm 53 dB 62 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 194 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.422 W/m2K -3 dB 1 dB
Detail IFC4 LOD300 XLSX

A0230

Ribs / joists 475 mm 69 dB 46 dB
On-lying material: Cement screed
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 307 kg/m2 -3 dB 1 dB
Verified calculation ≈ 0.296 W/m2K -7 dB 6 dB
Detail IFC4 LOD300 XLSX

A0231

Ribs / joists 445 mm 67 dB 48 dB
On-lying material: Cement screed
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 304 kg/m2 -3 dB 1 dB
Verified calculation ≈ 0.381 W/m2K -7 dB 5 dB
Detail IFC4 LOD300 XLSX

A0232

Ribs / joists 450 mm 66 dB 49 dB
On-lying material: Anhydrite
Additional insulation: Glass wool with dynamic stiffness s' of ≤ 9 [MN/m³]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 241 kg/m2 -3 dB 1 dB
Verified calculation ≈ 0.297 W/m2K -7 dB 5 dB
Detail IFC4 LOD300 XLSX

A0233

Ribs / joists 420 mm 63 dB 52 dB
On-lying material: Anhydrite
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 238 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.382 W/m2K -6 dB 4 dB
Detail IFC4 LOD300 XLSX

A0234

Ribs / joists 410 mm 53 dB 62 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

with dampening and floor construction 158 kg/m2 -3 dB 1 dB
Verified calculation ≈ 0.415 W/m2K -3 dB 1 dB
Detail IFC4 LOD300 XLSX

A0245

Ribs / joists 500 mm 70 dB 45 dB
On-lying material: Cement screed
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 364 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.325 W/m2K -7 dB 5 dB
Detail IFC4 LOD300 XLSX

A0246

Ribs / joists 475 mm 67 dB 48 dB
On-lying material: Anhydrite
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 298 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.325 W/m2K -7 dB 5 dB
Detail IFC4 LOD300 XLSX

A0247

Ribs / joists 465 mm 55 dB 60 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 216 kg/m2 -3 dB 0 dB
Verified calculation ≈ 0.349 W/m2K -3 dB 1 dB
Detail IFC4 LOD300 XLSX

A0248

Ribs / joists 525 mm 80 dB 30 dB
On-lying material: Cement screed
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Ceiling covering layer 2: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 536 kg/m2 0 dB 2 dB
Verified calculation ≈ 0.319 W/m2K -9 dB 12 dB
Detail IFC4 LOD300 XLSX

A0249

Ribs / joists 500 mm 80 dB 31 dB
On-lying material: Anhydrite
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Ceiling covering layer 2: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 470 kg/m2 -3 dB 4 dB
Verified calculation ≈ 0.32 W/m2K -11 dB 13 dB
Detail IFC4 LOD300 XLSX

A0250

Ribs / joists 490 mm 76 dB 39 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Ceiling covering layer 2: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 389 kg/m2 -5 dB 2 dB
Verified calculation ≈ 0.343 W/m2K -8 dB 7 dB
Detail IFC4 LOD300 XLSX

A0251

Ribs / joists 525 mm 80 dB 30 dB
On-lying material: Cement screed
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Smoothed joints

with dampening, floor construction and ceiling covering 526 kg/m2 -2 dB 4 dB
Verified calculation ≈ 0.315 W/m2K -12 dB 15 dB
Detail IFC4 LOD300 XLSX

A0252

Ribs / joists 500 mm 80 dB 33 dB
On-lying material: Anhydrite
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Smoothed joints

with dampening, floor construction and ceiling covering 460 kg/m2 -5 dB 4 dB
Verified calculation ≈ 0.316 W/m2K -14 dB 14 dB
Detail IFC4 LOD300 XLSX

A0253

Ribs / joists 490 mm 74 dB 41 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Smoothed joints

with dampening, floor construction and ceiling covering 379 kg/m2 -5 dB 2 dB
Verified calculation ≈ 0.338 W/m2K -9 dB 7 dB
Detail IFC4 LOD300 XLSX

A0254

Ribs / joists 510 mm 80 dB 32 dB
On-lying material: Cement screed
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 520 kg/m2 -4 dB 4 dB
Verified calculation ≈ 0.325 W/m2K -14 dB 16 dB
Detail IFC4 LOD300 XLSX

A0255

Ribs / joists 485 mm 80 dB 35 dB
On-lying material: Anhydrite
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 454 kg/m2 -7 dB 4 dB
Verified calculation ≈ 0.325 W/m2K -16 dB 15 dB
Detail IFC4 LOD300 XLSX

A0256

Ribs / joists 475 mm 72 dB 43 dB
On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Cement panels, glued on sub-floor
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

with dampening, floor construction and ceiling covering 373 kg/m2 -5 dB 2 dB
Verified calculation ≈ 0.349 W/m2K -10 dB 8 dB
Detail IFC4 LOD300 XLSX