Components

Construction assembly A2425

Lignum ID-№
A2425
Catalog number
A.3.04.WolfMASC5
Source of construction assembly
18-001770-PR03 GAS 01-F03-04-de-01, Year 2018
Base structure
Solid wood panel
Paneling
Without substructure, directly sheathed
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
355 mm
Weight
289 kg/m2
U-value
≈ 0.300 W/m2K
GWP
30.20 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of solid timber, without sheathing, double ceiling covering. Without substructure, directly mounted, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 40 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 64 dB
C dB
C50-3150 dB
Values of footfall sound insulation
Ln,w 45 dB
CI dB
CI50-2500 dB

Graphic

On-lying material: Phone Star TRI
Impact sound insulation: Akustic EP3
Dampening on Supporting structure: Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB
Bond: no composite action
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Coupling: Wood lath b=40mm
Ceiling covering 1st layer: Phone Star TRI
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Phone Star TRI Wolf Bavaria 30 mm 36 kg/m2 - - 03.013 91.062
Impact sound insulation Akustic EP3 Isover 20 mm 2.5 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB Sto 80 mm 132 kg/m2 - - 03.011 91.062
Bond no composite action - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 140 mm 65.8 kg/m2 1000 mm 1000 mm 07.002 91.047
Bond Stiff, execution of the prior art. - - - - - - -
Coupling Wood lath b=40mm Generic product, Origin mark Swiss wood 60 mm 29.4 kg/m2 - 312 mm 07.011 91.052
Ceiling covering 1st layer Phone Star TRI Wolf Bavaria 12.5 mm 15 kg/m2 - - 03.013 91.062
Ceiling covering layer 2 Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface / treatment Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 28 30 31 31 34 43 50 54 55 61 61 67 74 80 85 91 97 103 109 110 110 110
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 53 54 56 59 59 53 49 48 51 47 50 47 43 40 38 35 32 29 26 23 18 13

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
79760.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
64731.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
15009.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
854.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
833.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
340.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
492.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
20.3
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
712.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
711.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
224.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
487
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
141.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
122.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
117
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
19.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
30.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
23.2
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
156.9333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
42.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)