Components

Construction assembly A2505

Lignum ID-№
A2505
Catalog number
A.3.04.WolfMASC13
Source of construction assembly
18-001770-PR02 PB X15-F03-04-de-01, Year 2018
Base structure
Solid wood panel
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
308 mm
Weight
261 kg/m2
U-value
≈ 0.258 W/m2K
GWP
34.00 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of solid timber, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 40 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 66 dB
C -2 dB
C50-3150 -5 dB
Values of footfall sound insulation
Ln,w 43 dB
CI 0 dB
CI50-2500 5 dB

Graphic

Flooring: Floor heating system Therm38 longitudinal grooves
Separating layer: PowerFloor mit Rohrfräsung für FBH
On-lying material: Phone Star TRI
Impact sound insulation: Akustic EP3
Dampening on Supporting structure: Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB
Bond: no composite action
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 18 mm 21.6 kg/m2 - - 03.007 91.063
Separating layer PowerFloor mit Rohrfräsung für FBH Wolf Bavaria 20 mm 3.3 kg/m2 - - - -
On-lying material Phone Star TRI Wolf Bavaria 30 mm 36 kg/m2 - - 03.013 91.062
Impact sound insulation Akustic EP3 Isover 20 mm 2.5 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB Sto 80 mm 132 kg/m2 - - 03.011 91.062
Bond no composite action - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 140 mm 65.8 kg/m2 1000 mm 1000 mm 07.002 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 31 31 35 41 43 47 53 55 59 63 68 71 77 80 85 86 86 83 84 87 85
Calculation Lignum/Kühn and Blickle 30 33 36 38 41 44 45 45 41 44 41 44 46 49 49 49 49 58 67 74 83 91
Impact sound (Ln) Measurement Ift Rosenheim 56 59 54 51 51 49 48 48 47 45 42 39 35 33 28 23 19 14 9 7 6
Calculation Lignum/Kühn and Blickle 50 51 51 51 52 53 54 57 64 64 70 70 71 71 74 77 80 74 68 64 58 53

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
78933.6
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
65455.6
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13444
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
694.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
677
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
335.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
341.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
17.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
536
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
534.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
199.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
158.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
141.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
136.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
16.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
34
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
28.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.9
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
111.46666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
30.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)