LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0093

Lignum ID-№
C0093
Catalog number
C.1.03.K7
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Sheathing
Sheathed on both sides
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 442
Construction height
280 mm
Weight
256 kg/m2
U-value
≈ 0.188 W/m2K
GWP
47.90 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofstud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed on both sides, leftside double sheathed, rightside double sheathed. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 61 dB
C -5 dB
C50-3150 -12 dB

Graphic

Surface leftside: Glued joints/smoothed
Sheathed leftside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sheathed leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Plasterboard type A
Covering rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -
Sheathed leftside 2nd layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Sheathed leftside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 140 mm 6.6 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 140 mm 4.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Sheathed rightside 2nd layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 20 mm 157 kg/m2 - 834 mm - -
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 30 mm 1.4 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 40 mm 1.3 kg/m2 - - 10.008 91.173
Covering rightside1st layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Covering rightside 2nd layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
81835
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
73989
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7819
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
367.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
358.10
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
248.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
109.90
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
9.40
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
153.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
153.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
43.70
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
109.30
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.50
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
213.70
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
204.70
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
204.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.90
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
47.90
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
45.30
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.60
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
12.80
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)