LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0902

Lignum ID-№
A0902
Catalog number
A.3.02.N10
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Paneling
Substructure with rubber-mounted hangers
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
445 mm
Weight
1017 kg/m2
U-value
≈ 0.194 W/m2K
GWP
57.30 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of solid timber, without sheathing, simple ceiling covering. Substructure mounted with flexible hangers with cavity insulation, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 72 dB
C -6 dB
C50-3150 -17 dB
Values of footfall sound insulation
Ln,w 40 dB
CI 3 dB
CI50-2500 18 dB

Graphic

On-lying material: Cement screed
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 80 mm 176 kg/m2 - - 04.006 91.136
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 200 mm 94 kg/m2 1000 mm 1000 mm 07.002 91.047
Bond no composite action - - - - - - -
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 93 mm 730.1 kg/m2 - 1000 mm - -
Battens / profiles CD-ceiling profile b=60mm Fermacell, Knauf, Rigips, Protektor 27 mm 1.1 kg/m2 60 mm 500 mm 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 80 mm 2.6 kg/m2 - - 10.008 91.173
Ceiling covering 1st layer Plasterboard type A Knauf, Rigips 15 mm 11 kg/m2 - - 03.008 91.064
Surface / treatment Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
129807
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
113943
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
15758
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
975.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
954.90
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
467.10
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
487.90
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
20.40
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
771.10
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
769.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
290.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
479.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.10
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
204.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
185.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
177.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
7.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
19.30
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
57.30
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
50.00
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.30
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
154.73
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
42.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)