LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0376

Lignum ID-№
C0376
Catalog number
C.3.03.IW250B
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
Sheathed on one side
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 444
Construction height
199 mm
Weight
368 kg/m2
U-value
≈ 0.329 W/m2K
GWP
23.00 kg CO2-eq/m2
Type sound insulation
Calculation
Partition wall single shellconsisting of a basic construction ofBRESTA Solid Timber System without cavity insulation in the supporting structure. Sheathed on one side, leftside single sheathed. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 50 dB
C -3 dB
C50-3150 dB

Graphic

Surface leftside: Innenputz, verspachtelt
Sheathed leftside 1st layer: Plasterboard type A
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa * s/m]
Covering rightside1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface rightside: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139
Sheathed leftside 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Bond Stiff, execution of the prior art. - - - - - - -
Support Bresta Solid timber panel Tschopp 100 mm 49 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 36 mm 282.6 kg/m2 - 834 mm - -
Battens / profiles Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 30 mm 1.4 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 30 mm 1 kg/m2 - - 10.008 91.173
Covering rightside1st layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 15 mm 16.5 kg/m2 - - 03.007 91.063
Surface rightside Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 19 21 23 25 25 25 33 38 46 52 59 65 72 78 83 89 95 101 107 110 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
50600.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
44279.7
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6312.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
676.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
667.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
331.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
337.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8.8
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
582.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
581.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
243.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
337.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
96.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
87.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
87.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.199999999999998
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
23
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
19.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.6
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)