LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2526

Lignum ID-№
A2526
Catalog number
A.3.04.WolfMASB4X
Source of construction assembly
18-001770-PR02 PB X27-F03-04-de-01, Year 2018
Base structure
Solid wood panel
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
190 mm
Weight
106 kg/m2
U-value
≈ 0.323 W/m2K
GWP
20.40 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of solid timber, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation and with dry screed.
Values of airborne sound insulation
Rw 54 dB
C -2 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 56 dB
CI 1 dB
CI50-2500 4 dB

Graphic

On-lying material: Phone Star TRI
Bond: no composite action
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Phone Star TRI Wolf Bavaria 30 mm 36 kg/m2 - - 03.013 91.062
Bond no composite action - - - - - - -
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 140 mm 65.8 kg/m2 1000 mm 1000 mm 07.002 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 27 36 48 60 62 69 74 76 79 83 86 87 87 89 89 91 91 88 88 90 87
Calculation Lignum/Kühn and Blickle 25 28 31 33 36 39 40 40 36 39 36 39 41 44 44 44 44 53 62 69 78 87
Impact sound (Ln) Measurement Ift Rosenheim 67 66 66 67 67 64 61 58 53 47 41 34 29 26 18 14 12 10 8 8 9
Calculation Lignum/Kühn and Blickle 55 56 56 56 57 58 59 62 69 69 75 75 76 76 79 82 85 79 73 69 63 57

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
53108.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
45823.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7302
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
654.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
645.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
279.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
366.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
9.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
558.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
557.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
199.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
358.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
96.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
88
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
80.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
7.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
20.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
16.3
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
114.76666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
31.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)